V-PRO™ maX 2 Low Temperature Sterilization System

  • Capacity – Process up to 50lbs in 28 minutes, or 11lbs in as quick as 16 minutes
  • Features – The most throughput of any low temperature sterilizer
  • Compatibility – Compatible with the widest range of medical devices and materials, including 3D-printed materials

Delivering unparalleled productivity for day-to-day Operating Room needs, the V-PRO maX 2 Low Temperature Sterilization System is designed for use in the terminal sterilization of medical devices. STERIS’s V-PRO maX 2 Sterilizer features the Fast Non Lumen cycle, allowing you to sterilize devices like cameras, telescopes, batteries, and laryngoscope blades in just 16 minutes.

How V-PRO maX 2 Low Temperature Sterilization System Works

This Low Temperature Sterilization System using proprietary Sterilant is intended for use in the terminal Sterilization of properly prepared (cleaned, rinsed, and dried, refer to Cleaning, Rinsing, and Drying in the Operator’s Manual) medical devices in Healthcare Facilities. The preprogrammed Sterilization Cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues.

The V-PRO maX 2 Sterilizer offers five cycles to efficiently sterilize the widest range of surgical instruments and medical devices using our proprietary vaporized hydrogen peroxide technology:

  • Overall Sterilizer Dimensions: can be installed recessed or with a cabinet package
  • Cabinet (DD): 33 x 72 x 40-15/16″ (838 x 1829 x 1040 mm)
  • Recessed/Cabinet (SD): 33 x 72 x 38-5/16″ (838 x 1829 x 973 mm)
  • Chamber Size is 17 x 15 x 32-1/2″ (432 x 381 x 826 mm) with 4.8 cubic feet (136 L) of volume
  • Utility Requirements – no plumbing, special ventilation, or air supply. Only a standard 20amp dedicated wall outlet is needed

Connectivity and Electronic Record Management with ConnectAssure™ Technology

Seamlessly connect and get immediate results from your V-PRO maX 2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Software and many of the other leading instrument tracking systems.

 

What can the V-PRO maX 2 Low Temperature Sterilizer sterilize?

The V-PRO maX 2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.

How fast can the V-PRO maX 2 Low Temperature Sterilizer sterilize?

The V-PRO maX 2 Low Temperature Sterilizer has four cycles that range from very fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:

  • The Lumen Cycle will process rigid lumened devices in around 52 minutes
  • The Flexible Cycle will process flexible scopes in around 35 minutes
  • The Non Lumen Cycle will process general stainless steel and non lumened devices, including da Vinci endoscopes, in around 28 minutes

For the fastest turn-around, the Fast Non Lumen Cycle will process general stainless steel and non lumened instruments in pouches or pouched trays in around 16 minutes.

What STERIS accessories are designed to work with the V-PRO maX 2 Low Temperature Sterilizer?

  • Celerity™ HP Biological Indicators
  • Celerity™ HP Challenge Packs
  • Celerity™ HP Multivariable Chemical Indicator
  • VAPROX™ HC Sterilant with RFID label
  • Verdoc™ Vaporized VH2O2 Record Card with Process
  • PRO-LITE Sterilization Trays, Instrument Organizers, and Silicone Mats
  • Vis-U-All™ Low Temperature Sterilization Pouches and Tubing